Dell R610 owner manual reported a microprocessor

Models: R610

1 184
Download 184 pages 23.25 Kb
Page 27
Image 27
reported a microprocessor

Table 1-1. LCD Status Messages (continued)

Code

Text

Cause

Corrective Actions

 

 

 

 

E141F

CPU #

The system BIOS has

Remove AC power to the

 

protocol

reported a processor

system for 10 seconds and

 

error. Power

protocol error.

restart the system.

 

cycle AC.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help."

E1420 CPU Bus

The system BIOS has

parity error.

reported a microprocessor

Power cycle

bus parity error.

AC.

 

Remove AC power to the system for 10 seconds or clear the SEL.

If the problem persists, see "Getting Help."

E1422

CPU # machine

The system BIOS has

Remove AC power to the

 

check error.

reported a machine check

system for 10 seconds and

 

Power cycle

error.

restart the system.

 

AC.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help."

 

 

 

 

E1610

Power Supply

Specified power supply was

See "Troubleshooting

#(### W) removed or is missing from Power Supplies."

 

missing.

the system.

 

 

Check power

 

 

 

supply.

 

 

 

 

 

 

E1614

Power Supply

Specified power supply has

See "Troubleshooting

 

# (### W)

failed.

Power Supplies."

 

error. Check

 

 

 

power supply.

 

 

 

 

 

 

E1618

Predictive

A power supply fan failure,

See "Troubleshooting

 

failure on

an over-temperature

Power Supplies."

 

Power Supply

condition, or power supply

 

 

# (### W).

communication error has

 

 

Check PSU.

caused the predictive

 

 

 

warning of an impending

 

 

 

power supply failure.

 

About Your System

27

Page 27
Image 27
Dell R610 owner manual reported a microprocessor