Dell R610 owner manual match in rank, count x,x, match in size, and geometry, and rank count

Models: R610

1 184
Download 184 pages 23.25 Kb
Page 49
Image 49
geometry:

Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

The following

Invalid memory

Ensure that the memory

DIMMs should

configuration. The specified

modules are installed in a

match in

DIMMs do not match in size,

valid configuration. See

geometry:

number of ranks, or number

"System Memory."

x,x,...

of data lanes.

 

The following

 

 

DIMMs should

 

 

match in rank

 

 

count: x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and geometry:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and rank count:

 

 

x,x,...

 

 

 

 

 

Thermal sensor

Invalid memory

Ensure that the memory

not detected on x configuration. A mismatched

modules are installed in a

 

DIMM is installed.

valid configuration. See

 

 

"System Memory."

 

 

 

Time-of-day

Faulty battery or faulty chip.

See "Troubleshooting the

clock stopped

 

System Battery."

 

 

 

Time-of-day not

Incorrect Time or Date

Check the Time and Date

set - please run

settings; faulty system

settings. See "Using the

SETUP program

battery.

System Setup Program and

 

 

UEFI Boot Manager." If the

 

 

problem persists, replace the

 

 

system battery. See "System

 

 

Battery."

About Your System

49

Page 49
Image 49
Dell R610 owner manual match in rank, count x,x, match in size, and geometry, and rank count