Dell R610 owner manual 1. LCD Status Messages continued

Models: R610

1 184
Download 184 pages 23.25 Kb
Page 32
Image 32
Manual background

Table 1-1. LCD Status Messages (continued)

Code

Text

Cause

Corrective Actions

 

 

 

 

E1A15

SAS cable B

SAS cable B is missing or

Reseat the cable. If the

 

failure.

bad.

problem persists, replace

 

Check

 

cable.

 

connection.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help."

 

 

 

 

E1A1D

Control panel

USB cable to the control

Reseat the cable. If the

 

USB cable not

panel is missing or bad.

problem persists, replace

 

detected.

 

cable.

 

Check cable.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help."

 

 

 

 

E2010

Memory not

No memory was detected in

Install memory or reseat

 

detected.

the system.

the memory modules. See

 

Inspect

 

"System Memory" or

 

DIMMs.

 

"Troubleshooting System

 

 

 

Memory."

 

 

 

 

E2011

Memory

Memory detected, but is

See "Troubleshooting

 

configuration

not configurable. Error

System Memory."

 

failure.

detected during memory

 

 

Check DIMMs.

configuration.

 

 

 

 

 

E2012

Memory

Memory configured, but is

See "Troubleshooting

 

configured

unusable.

System Memory."

 

but unusable.

 

 

 

Check DIMMs.

 

 

 

 

 

 

E2013

BIOS unable

The system BIOS failed to

See "Troubleshooting

 

to shadow

copy its flash image into

System Memory."

 

memory. Check

memory.

 

 

DIMMs.

 

 

 

 

 

 

E2014

CMOS RAM

CMOS failure. CMOS

Remove AC power to the

 

failure.

RAM not functioning

system for 10 seconds and

 

Power cycle

properly.

restart the system.

 

AC.

 

If the problem persists,

 

 

 

see "Getting Help."

32

About Your System

Page 32
Image 32
Dell R610 owner manual 1. LCD Status Messages continued