Dell R610 owner manual 1. LCD Status Messages continued

Models: R610

1 184
Download 184 pages 23.25 Kb
Page 30
Image 30
Manual background

Table 1-1. LCD Status Messages (continued)

Code

Text

Cause

Corrective Actions

 

 

 

 

E1714

Unknown

The system BIOS has

Remove AC power to the

 

error. Review

determined there has been

system for 10 seconds and

 

& clear SEL.

an error in the system, but

restart the system.

 

 

is unable to determine its

If the problem persists,

 

 

origin.

 

 

see "Getting Help."

 

 

 

 

 

 

 

E1715

Fatal I/O

The system BIOS has

Check the SEL for details

 

error. Review

determined there has been

of the error message and

 

& clear SEL.

an error in the system.

then clear the SEL.

 

 

 

Remove AC power to the

 

 

 

system for 10 seconds and

 

 

 

restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help."

 

 

 

 

E1716

Chipset IERR

The system BIOS has

Check the SEL for details

 

Bus ## Dev ##

reported a chipset internal

of the error message and

 

Function ##.

error that resides in bus

then clear the SEL.

 

Review &

##, device ##,

Remove AC power to the

 

clear SEL.

function##.

system for 10 seconds and

 

 

 

restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help."

 

 

 

 

E1717

CPU ##

The system BIOS has

Check the SEL for details

 

internal

determined that the

of the error message and

 

error. Review

specified processor has had

then clear the SEL.

 

& clear SEL.

an internal error.

Remove AC power to the

 

 

 

system for 10 seconds and

 

 

 

restart the system.

See "Troubleshooting the Processors." If the problem persists, see "Getting Help."

30

About Your System

Page 30
Image 30
Dell R610 owner manual 1. LCD Status Messages continued