To resolve the problem and remove the LCD message, refer to the corrective actions in the following table.

NOTE: The following LCD status messages are displayed in the Simple format. See “Setup Menu“to select the format in which the messages are displayed.

Table 1-1. LCD Status Messages

Code

Text

Cause

Corrective Actions

 

 

 

 

E1000

Failsafe

Check the system event log

Remove AC power to the

 

voltage

for critical failure events.

system for 10 seconds or

 

error.

 

clear the SEL.

 

Contact

 

If the problem persists,

 

support.

 

 

 

see "Getting Help."

 

 

 

 

 

 

 

E1114

Ambient Temp

Ambient temperature has a

See "Troubleshooting

 

exceeds

reached a point outside of

System Cooling

 

allowed

the allowed range.

Problems."

 

range.

 

 

 

 

 

 

E1116

Memory

Memory has exceeded

Remove AC power to the

 

disabled,

allowable temperature and

system for 10 seconds and

 

temp above

has been disabled to

restart the system.

 

range. Power

prevent damage to the

See "Troubleshooting

 

cycle AC.

components.

 

System Cooling

 

 

 

 

 

 

Problems."

 

 

 

If the problem persists,

 

 

 

see "Getting Help."

 

 

 

 

E1210

Motherboard

CMOS battery is missing or

See "Troubleshooting the

 

battery

the voltage is outside of the

System Battery."

 

failure.

allowable range.

 

 

Check

 

 

 

battery.

 

 

E1211 RAID

RAID battery is either

Controller

missing, bad, or unable to

battery

recharge due to thermal

failure.

issues.

Check

 

battery.

 

Reseat the RAID battery connector. See "Installing a RAID Battery" and "Troubleshooting System Cooling Problems."