Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Embedded NICx and

The OS NIC interface is

Check the system

NICy:

disabled in BIOS. The

management software or the

OS NIC=DISABLED,

Management Shared NIC

System Setup program for

Management

interface is disabled in

NIC settings. If a problem is

Shared NIC=

management tools.

indicated, see

DISABLED

 

"Troubleshooting a NIC."

 

 

 

Embedded NICx and

The OS NIC interface is

Check the system

NICy:

disabled in BIOS. The

management software or the

OS NIC=DISABLED,

Management Shared NIC

System Setup program for

Management

interface is enabled in

NIC settings. If a problem is

Shared NIC=

management tools.

indicated, see

ENABLED

 

"Troubleshooting a NIC."

 

 

 

Error 8602 -

Mouse or keyboard cable is

Reseat the mouse or

Auxiliary Device

loose or improperly

keyboard cable.

Failure. Verify

connected.

 

that mouse and

Defective mouse or keyboard. Ensure that the mouse or

keyboard are

 

keyboard is operational. See

securely

 

 

"Troubleshooting a USB

attached to

 

 

Device."

correct

 

 

 

connectors.

 

 

 

 

 

Gate A20 failure

Faulty keyboard controller;

See "Getting Help."

 

faulty system board.

 

General failure The operating system is unable to carry out the command.

This message is usually followed by specific information. Note the information, and take the appropriate action to resolve the problem.

Invalid

An invalid system

Run the System Setup

configuration

configuration caused a

program and review the

information -

system halt.

current settings. See "Using

please run SETUP

 

the System Setup Program

program.

 

and UEFI Boot Manager."

42