9

Troubleshooting

To get help with your Dell PowerEdge RAID Controller (PERC) 9 series of cards, you can contact your Dell Technical Service representative or see dell.com/support.

BIOS configuration utility error messages

The controller BIOS read-only memory (ROM) provides Int 13h functionality (disk I/O) for the virtual disks connected to the controller. You can boot from or access the physical disks without a driver.

Discovery error message

Error Message:

A discovery error has occurred, please power cycle the system

 

and all the enclosures attached to this system.

Probable

This message indicates that discovery did not complete within 120 seconds. The

Cause:

SAS cables for your system might be improperly connected.

Corrective

Check the cable connections and fix any problems. Restart the system.

Action:

 

Extra enclosure error message

Error Message:

There are X enclosures connected to connector Y, but only

 

maximum of 4 enclosures can be connected to a single SAS

 

connector. Please remove the extra enclosures then restart your

 

system.

Probable

This message is displayed when the BIOS detects more than four enclosures

Cause:

connected to a single SAS connector.

Corrective

You must remove all additional enclosures and restart your system.

Action:

 

Missing disks in virtual disk error message

Error Message: The following virtual disks have missing disks: (x). If you proceed (or load the configuration utility), these virtual disks will be marked OFFLINE and will be inaccessible. Please check your cables and ensure all disks are present. Press any key to continue, or 'C' to load the configuration utility.