Probable

The message indicates that some configured disks were removed. If the disks were

Cause:

not removed, they are no longer accessible. The SAS cables for your system might

 

be improperly connected.

Corrective

Check the cable connections and fix any issues. Restart the system. If there are no

Action:

cable problems, press any key or <C> to continue.

Previous configuration of disks removed error message

Error Message:

All of the disks from your previous configuration are gone. If

 

this is an unexpected message, then please power off your

 

system and check your cables to ensure all disks are present.

 

Press any key to continue, or press <C> to load the

 

configuration utility.

Probable

The message indicates that some configured disks were removed. If the disks were

Cause:

not removed, they are no longer accessible. The SAS cables for your system might

 

be improperly connected.

Corrective

Check the cable connections and fix any issues before restarting the system. If

Action:

there are no cable problems, press any key or <C> to continue.

Missing virtual disks error message

Error Message:

The following virtual disks are missing: (x). If you proceed

 

(or load the configuration utility), these virtual disks will

 

be removed from your configuration. If you wish to use them at

 

a later time, they will have to be imported. If you believe

 

these virtual disks should be present, please power off your

 

system and check your cables to ensure all disks are present.

 

Press any key to continue, or 'C' to load the configuration

 

utility.

Probable

The message indicates that some configured disks were removed. If the disks were

Cause:

not removed, they are no longer accessible. The SAS cables for your system might

 

be improperly connected.

Corrective

Check the cable connections and fix any issues. Restart the system. If there are no

Action:

cable problems, press any key or <C> to continue.

Dirty cache data error message

Error Message: The following virtual disks are missing: (x). If you proceed (or load the configuration utility), these virtual disks will be removed from your configuration. If you wish to use them at a later time, they will have to be imported. If you believe these virtual disks should be present, please power off your system and check your cables to ensure all disks are present. Press any key to continue, or 'C' to load the configuration utility. The cache contains dirty data, but some virtual disks are missing or will go offline, so the cached data cannot be written to disk. If this is an unexpected error, then please

99

Page 99
Image 99