Dukane 8107HWI user manual Maintenance, Type number 456-8104HW Replacing the lamp

Models: 8107HWI

1 119
Download 119 pages 45.2 Kb
Page 99
Image 99
Maintenance
lamp cover

Maintenance

Maintenance

Replacing the lamp

A lamp has finite product life. Using the lamp for long periods of time could cause the pictures darker or the color tone poor. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. Preparation of a new lamp and early replacement are recommended. To prepare a new lamp, make contact with your dealer and tell the lamp type number.

Type number : 456-8104HW

Replacing the lamp

1. Turn the projector off, and unplug the power cord. Allow the projector to cool for at least 45 minutes.

2. Prepare a new lamp. If the projector is mounted on a ceiling, or if the lamp has broken, also ask the dealer to replace the lamp.

In case of replacement by yourself, follow the following procedure.

3. Loosen the screw (marked by arrow) of the lamp cover and then slide and lift the lamp cover to the

side to remove it. 4. Loosen the 2 screws (marked by arrow) of the lamp,

and slowly pick up the lamp by the handle. Never loosen any other screws.

5. Insert the new lamp, and retighten firmly the 2 screws of the lamp that are loosened in the previous

process to lock it in place.

6. While putting the interlocking parts of the lamp cover and the projector together, slide the lamp cover back in place. Then firmly fasten the screw of the lamp cover.

7. Turn the projector on and reset the lamp time using the LAMP TIME item in the OPTION menu.

(1) Press the MENU button to display a menu.

(2) Point at the ADVANCED MENU in the menu using Replacing the lamp the ▼/▲ button, then press the ► button.Type number : 456-8104HW

(3) Point at the OPTION in the left column of the menu Handle using the ▼/▲button, then press the ► button.

(4)Point at the LAMP TIME using the ▼/▲ button, then press the ► button. A dialog will appear.

(5)Press the ► button to select “OK” on the dialog. It performs resetting the lamp time.

In case of replacement by yourself, follow the following procedure. CAUTION ►Do not touch any inner space of the projector, while the lamp is taken out.

NOTE • Please reset the lamp time only when you have replaced the lamp, for a suitable indication about the lamp.