Edition
Service
Manual 12. Function Sequences 13 9010 12
Type Page
1566
Program selector
13
p<
B1
61
11
12 14
21
22 24
43
3
4
X79
X179
X179
52
2
5
E
B
13
S5
S5
14
5
10
Y11
Y13
Y12
Y24
Y22
K51
C
ab
5
6
16
6
1a
2
a
1
32
45
ab
ab
ba
62314
51423
X72 X73
X72 X73
X81
X181
X181
X81
F
X77
X79
12
1570
B = Power supply, see function
diagram ''Power Supply and Start''
(1) Timer row 13
a: Level 1
b: Level 2
(2) Shackle X77:5-6
shackle closed: only high water level
shackle cut-off: low and high water level
(3) B1 Level control
E F = voltage supply to other
function sequences
(4) Timer row 2
(5) Timer row 1
(6) Timer row 14
a: Inlet valve Y11
b: Inlet valve Y13
(7) Timer row 5
a: Inlet valve Y12
b: Inlet valve Y12
(8) Timer row 10
a: Inlet valve Y22
b: Inlet valve Y24
(9) Y11 Water valve, cold, detergent 1
(10) Y13 Water valve, cold, detergent 3
(11) Y12 Water valve, cold, detergent 2
(12) Y24 Water valve, hot, drum
(13) Y22 Water valve, hot, detergent 2
(14) K51 Relay, timer rapid advance
(15) C = Power supply, see function
diagram ''Power Supply and Start''
Timer
Timer
Pogram
selector
Level
control
Timer
1 Cold
2 Warm
3 Hot
4 Perm. press