Service

34. Water inlet valve

Manual

Repair instructions

Lime deposits can block the valve diaphragm hole and prevent the valve from functioning properly.

It is therefore a good idea to take apart and clean the valve regularly depending on operation conditions and the degree of polutants and lime content present in the water.

Valve does not open

Check that there is voltage supply to the coil.

Measure the voltage supply to the coil to check for a possible power failure or short circuit.

Take apart the valve and check the valve diaphragm openings.

Check the inlet filter and clean it when necessary.

Remove the coil and clean the coil core surfaces.

Valve does not close

Check that there is no voltage across the coil. Normally the valve is closed when the coil is not energized.

Check the return spring.

Check the diaphragm (pilot pressure opening).

Dismantling of the valve

Fig. 1. Carefully pry off the valve coil using a screw

3driver.

Fig. 2. Turn and lift the valve cover using a special tool

4and a wrench. (The special tool is attached to

one of the machine’s water hoses upon

Fig.

3

1187

4

Special tool

0906

5

5

delivery.)

1181

Page 125
Image 125