Service |
|
|
|
|
| ||
| 14 | 9002 | 1 | 21 | |||
Manual | 21. Automatic Unit | ||||||
Type | Edition | Page | |||||
|
|
|
|
|
|
|
Components
Fig.
1
P1 Electronic
K1 Relay, wash speed
K2 Relay, wash speed
K4 Relay, spin speed
K21 Relay, heating
S Panel display with
B1 Level switch — to monitor high and low water levels. The level sensor also protects the machine from dryout and spinning with water in the machine.
T10 Transformer — power supply for the electronic unit. Adaptable to different main voltages: 110 V, 208 V, 220 V, 240 V.
1
B1
T10
S
P1
K21 | K1 | K2 | K4 |