Drain
The drain valve closes when the control valve Y1 (2) is activated (cold water supply must be open).
The valve will not close until the door is locked (this is when point C receives voltage, see section ”Safety lock and power supply”). Control valve Y1 is controlled by row 16a (1) which itself is closed when the drain valve (2) should be closed.
16 Drain valve
|
|
|
|
|
|
| Drain |
|
|
| down | Drain | Rinse1 | Drain |
| Drain/ | Extract. |
| Drain/ Extract. |
|
| Stop |
| Extract. |
|
|
|
|
| Open | Start |
| |||
|
|
|
|
|
|
|
|
|
|
| Cool |
|
|
|
|
|
|
|
|
|
| Rinse 4 |
| Drain/ |
|
|
|
|
|
|
|
| |||
|
| Pre wash |
|
|
|
| Main wash |
|
|
|
| Rinse 2 |
|
| Rinse 3 |
|
|
|
|
|
| Spin down |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 10 11 12 13 14 15 16 17 18 19 20 | 21 22 23 | 24 | 25 26 | 27 | 28 29 30 | 31 | 32 | 33 34 35 | 36 37 | 38 39 40 | 41 42 | 43 | 44 45 46 | 47 48 49 50 51 | 52 | 53 | 54 | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(30'') | 30'' | P+ T+ | 1' | 30'' | L+ 30'' | 3'' | 27'' 30'' P+ 3' T+ | 1' 5' 1' 1' T- T- | 1' | 2' P+ 1' | L+ 1' | 1' 1' P+ 1' L+ 1' | 30'' | 30'' P+ 1' P+ 1' | L+ 1' 30'' 30'' | P+ 30'' P+ 30'' STOP | 30''/1' | L+ 1' 1' 3' | 3'' L+ 27'' 3'' 27'' 30'' 2' | O/S |
|