Service
Manual | 12. Operational sequences |
11 9002 1 12
Type Edition Page
Trouble shooting | 1 |
Fault indication
Fig. The microprocessor-controlled machines have an
1automatic trouble shooting program which continuously monitors the main functions. If a fault
Fig. | occurs in service, a nummerical code (see table | Error code |
|
2below) blinks on the control panel display.
When error code 01 or 02 are displayed, a restart can be done after the fault has been put right.
When the other codes are displayed, the main switch must be turned off and then on again before the machine can be restarted.
Built-in service program
There is a
2
3
2....
1 ....
1026
| Error code Error | Probable remedy/Solution | ||
| 01 | Water level not reached | Is the water | |
| 02 | Door lock in operative | Open and close door again. | |
|
|
| Push START for restart. | |
| 03 | Shortcircuit | Shortcircuit in temperature sensor or in the cable | |
|
| Water temperature over 98° C | between sensor and circuit board. | |
| 04 |
|
| |
| 05 | Water in machine | Check drain and level sensor system. | |
|
| before program start |
|
|
| 06 | Machine memory fault |
|
|
| 07 | Machine heats incorrectly | Check heating system and thermostat. | |
| 08 | Drain time too long | Check drain system. | |
| 09 |
|
| |
|
|
|
|
|