Service

Manual 12

Type Page
Edition
11 1

12. Operational sequences

1
1026
Error code Error Probable remedy/Solution
01 Water level not reached Is the water shut-off valve open? Push START restart.
02 Door lock in operative Open and close door again.
Push START for restart.
03 Shortcircuit Shortcircuit in temperature sensor or in the cable
between sensor and circuit board.
04 Water temperature over 98° C
05 Water in machine Check drain and level sensor system.
before program start
06 Machine memory fault
07 Machine heats incorrectly Check heating system and thermostat.
08 Drain time too long Check drain system.
09 Out-of-balance switch in operative
2
1
...
..
2
...
..
3
Error code
Trouble shooting
Fault indication
The microprocessor-controlled machines have an
automatic trouble shooting program which
continuously monitors the main functions. If a fault
occurs in service, a nummerical code (see table
below) blinks on the control panel display.
When error code 01 or 02 are displayed, a restart
can be done after the fault has been put right.
When the other codes are displayed, the main
switch must be turned off and then on again before
the machine can be restarted.
Built-in service program
There is a built-in service program which facilitates
function controls and fault tracing. With the
program, different switches and sensors, such as
the door safety lock and coin meter, can be
checked. It is also easy to direct and thereby check
the machine parts, such as motor, valves and door
safety lcok.
Fig.
1
9002
Fig.
2