Service
Manual | 12. Function Sequences |
13 | 9010 | 9 | 12 |
Type | Edition | Page |
Program Selector
1575
AB F = Power supply, see functions diagram "Power supply and start", F see functions diagram "Water filling"
(1)Timer row 15 a Rapid advance
(2)Timer row 1 b
Rapid adv. Cool down
(3)Timer row 3 a
Rapid adv. Short spinn
(4)Timer row 9 a Rapid adv. 1:st rinse
(5)Timer row 16 a Rapid adv. Pre wash
(6)S6 Switch Start + K51
(7)Shackle
(8)S3 Switch Door
(9)Timer row 4
(10)Timer row 3
Switches S12 – S14 : Option
(11)Switch S12 Short spinn
(12)Switch S13 No first rinse
(13)Switch S14 No pre wash
(14)Timer row 2 a Rapid adv. Open door
(15)K51 Coil for timer rapid advance
D= Power supply, see functions diagram "Power supply and start"