EverFocus ECOR264-4D1 1.9.2 RS-485 socket pin assignment, EKB-500 connection to several DVRs

Models: ECOR264-4D1 ECOR264-8D1

1 128
Download 128 pages 15.06 Kb
Page 18
Image 18
1.9.2RS-485 socket pin assignment

System expansion with RS-485 signal distributor

ATTENTION: Most signal distributors are unidirectional! This means that the signal only flows from the input towards the outputs. Therefore, e.g. the interconnection of several keyboards is not possible with these types of signal distributor!

1.9.2RS-485 socket pin assignment

The RS485 pin assignment is as follows:

1.9.3EKB-500 connection with network patch cable

For a simple, short distance installation, recorder and keyboard can be connected directly using a standard CAT5 network cable with an 8-pin connector at only one end, and at the other end the Pin 3 wire connected to RS485 “+” (plus) and the pin 6 wire connected to RS-485 “-“ (minus).

1.9.4EKB-500 connection to several DVRs

For long distance installations connecting several DVRs, please use a signal distributor to connect

For further details on keyboard connection, please refer to the EKB-500 manual.

RS-485 port communication settings are configured in the I/O CONTROL menu (Section 5.10.4 System Setup: I/O - control).

1.9.5Speed Dome Installation

Speed dome or telemetry receiver pan/tilt/zoom control is available through web browser or the optional PowerCon software if the DVR is connected to a network. Local telemetry control is provided by USB - mouse control or by the optional EKB-500 keyboard.

Supported protocols: EverFocus, Pelco-D, Pelco-P, Samsung, Transparent

Required DVR settings: RS-485 receiver address in CAMERA menu (Section 4.3)

RS-485 parameters and protocol in the I/O CONTROL menu (Section 5.10.4)

ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1, i.e. the address assigned to the dome / receiver in the DVR camera menu must be 1 below the address set in the dome / receiver itself!