HD Temperature:

Figure 4-12 Alarm & Event Menu – Event - HD Temperature

Log: Check box to record HDD temperature events in the log.

Buzzer: Check box to enable buzzer when hard drive’s temperature is over the “Temp. Warning Limit”.

Email Notify: Check box to enable email notification when HDD temperature is over the “Temp. Warning Limit”. Email operation requires that valid email settings have been entered in the Network Setting/Email setup screen.

Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and setting up Alarm Server in Network Setup menu)

Stop Recording: Check box to stop recording when HD’s temperature is over the “Temp. Warning Limit”.

Temp. Warning Limit: Sets the trigger temperature for HD Temperature event actions. Choose between 55°C /131°F or 85°C /185°F.

Alarm Output: This will transmit a signal through the alarm output. It can be set to either “NONE” (not active) or, “1” (active).

Output Type: Output action will be Transparent and cannot be changed (alarm output remains as long as the alarm condition is active).