Extron electronic MLC 62 IR D manual MLC 60 Series MediaLink Controllers SIS Control

Models: MLC 62 IR D

1 79
Download 79 pages 3.79 Kb
Page 63
Image 63

On the MLC 64, the LEDs are numbered as follows:

LED Number

LED Location

 

 

1

Transmit red

 

 

2

Transmit green

3, 4, 5, 6

Four LEDs behind “Display” text

 

 

7

Button row 1, first LED (button 1)

 

 

8

Button row 1, second LED (button 2)

9, 10, 11

Button row 2, LEDs 1 through 3

 

 

12, 13, 14

Button row 3, LEDs 1 through 3

 

 

15, 16, 17

Button row 4, LEDs 1 through 3

18, 19, 20

Button row 5, LEDs 1 through 3

 

 

21 through 32

Not used (The status is always 0.)

Each digit in the X21@ number can be 0 through 4, representing the following possible LED statuses:

0 = off

1 = dim

2 = on (bright)

3 = slow blink

4 = fast blink

NOTE: Unless otherwise indicated, commands are not case-sensitive.

MLC 60 Series MediaLink Controllers • SIS Control

57

Page 63
Image 63
Extron electronic MLC 62 IR D manual MLC 60 Series MediaLink Controllers SIS Control