General

Power supply

 

 

MLC 64 RS D

External

 

Input: 100-240 VAC, 50-60 Hz

 

Output: 12 VDC, 1 A, 12.0 watts

Remote volume control

10 VDC, supplied by the Extron device being controlled

Power input requirements

 

 

MLC 64 RS D

12 VDC, 0.4 A, max.

Remote volume control

Unmute mode: 0.2 watts, 18 mA, 10 VDC

 

Mute mode: 0.4 watts, 42 mA, 10 VDC

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling

Convection, no vents

Mounting

 

 

Rack mount

No

Furniture or wall mount

Mounts in a standard 2 gang US electrical junction box (1.50" depth) or with

 

included mud ring.

Enclosure type

Plastic

Enclosure dimensions

 

 

Faceplate

Fits the opening in a 2 gang Decora style wallplate.

Devices

4.2" H x 3.6" W x 2.5" D or 1.9" D*

 

Depth includes connectors and buttons. Allow enough depth in the junction

 

box for device plus cable clearance.

 

*Depth including the knob

 

3.61"

 

 

(9.17 cm)

 

 

1.13"

 

 

(2.87 cm)

 

 

 

4.19"

(10.64 cm)

RO

UND

 

 

 

 

OU

ND

 

 

 

1

 

 

 

 

 

 

MM

ON

CO

 

 

 

 

 

 

 

2

 

 

 

 

 

1

 

 

 

 

 

 

OUN

D

GR

 

 

 

 

 

 

Tx

/IR

 

 

 

 

 

 

 

 

OUN

D

GR

 

 

 

 

 

 

Tx

 

 

 

 

 

 

OUN

D

GR

 

 

VDC

+12

 

 

 

 

HOST/

CONFIG

DIGITAL

INPUT

RELAYS

N/O

IR/S

RS-232

PWR

12V 0.4AMAX

2.77”

(7.04 cm)

 

1.74"

 

(4.4 cm)

 

MLC 64 Rear

Product weight

1.1 lb (0.5 kg)

Shipping weight

3 lbs (2 kg)

Vibration

ISTA 1A in carton (International Safe Transit Association)

Regulatory compliance

 

Safety

CE, c-UL, UL

EMI/EMC

CE, C-tick, FCC Class A, ICES, VCCI Class A

Accessibility

Section 508 of the Rehabilitation Act (29 U.S.C. 794d)