Relay Functions (RS models only)

Pulse relay

X@*3*X# O

Rly X@*X2# ]

Example:

2*3*1O

Rly2*1 ]

Toggle relay

X@*2 O

Rly X@*X2# ]

Force relay on

X@*1 O

Rly X@*1 ]

Force relay off

X@*0 O

Rly X@*0 ]

View relay state

X@ O

X2# ]

Set the length X# of the pulse specified for relay port X@. Values for X# represent increments of 0.5 seconds and can range from 1 (0.5 seconds) to 255 (approximately

130 seconds). The MLC response includes status X2# for the specified relay port.

For X@: 1 = Relay 1; 2 = Relay 2.

For X2#: 0 = open (disengaged; 1 = closed (engaged).

Relay port 2 will remain closed for pulse intervals of 0.5 seconds.

Close and open relay port X@. Each time the command is issued, the MLC toggles between the On and Off states.

The MLC response includes status X2# for the specified relay port.

Set relay port X@ to remain closed (on).

Set relay port X@ to remain open (off).

Show state X2# of relay port X@. For X2#: 0 = open; 1 = closed.

Digital Input Data Port (RS models only)

View digital input state

]

X^ ]

View status X^ of the Digital

 

 

 

Input port. For X^:

 

 

 

0 = low; 1 = high.

Front Panel Lockout (Executive Mode)

 

 

Off

0X

Exe0 ]

Unlock front panel buttons.

On

1X

Exe1 ]

Lock all front panel buttons.

View

X

X1! ]

View front panel lockout status.

 

 

 

X1!. For X1!, 0 = off; 1 = on.

Device Naming

 

 

 

Set unit name

E X1@ CN }

IpnX1@ ]

Set name X1@ for the MLC. X1@

 

 

 

can be up to 24 alphanumeric

 

 

 

characters. The first character

 

 

 

must be alphabetic; the last

 

 

 

character cannot be a hyphen or

 

 

 

minus sign. No blank or space

 

 

 

characters are permitted.

Set unit name to factory

ECN }

IpnX4( ]

Set the name of the MLC to its

default

 

 

factory default name X4(.

 

 

 

X4( is:

 

 

 

MLC-62-RSfor RS models

 

 

 

MLC-62-IRfor IR models

 

 

 

MLC-64-RS-D for MLC 64

View unit name

E CN }

X1@ ]

Show the name of the MLC.