Extron electronic MLC 62 IR D manual Query LED status

Models: MLC 62 IR D

1 79
Download 79 pages 3.79 Kb
Page 67
Image 67

 

Command

ASCII Command

Response

Additional Description

 

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

 

 

 

 

 

 

 

Query LED status

 

 

 

 

 

View LED status

E LC }

X5) ]

X5) is a 32-digit number, of

 

 

 

 

 

 

 

which each digit represents the

 

 

 

 

status of an LED on the MLC

 

 

 

 

front panel.

On MLC 62 models, the LEDs are numbered as follows:

 

1

2

 

1 =Transmit red

 

 

 

 

 

 

 

 

2 = Transmit green

 

 

 

3

– 6

3-6 = Display text LEDs 1 through 4

 

DISPLAY

7 = Button row 1, first LED

7

ON

OFF

8

 

8 = Button row 1, second LED

 

 

VOLUME

 

 

9-12 = Volume text LEDs 1 through 4

13 – 17

9

– 12

 

 

13-17 = Volume LEDs 1 through 5

18

 

 

19

 

18

= Button row 2, first LED

 

 

 

19

= Button row 2, second LED

20

PC 21VIDEO

22

 

20

= Button row 3, first LED

 

21

= Button row 3, second LED

 

 

 

 

 

22

= Button row 3, third LED

23

LAPTOP

MUTE

25

 

23

= Button row 4, first LED

 

Extron

 

 

24

= Button row 4, second LED

 

 

 

 

 

 

 

 

25

= Button row 4, third LED

 

24

 

 

 

26-32 = Not used (Their status is always 0)

 

 

 

 

 

 

 

 

 

In X5), the LEDs are represented in descending order from 32 to 1; that is, the first digit represents LED 32, the second digit represents LED 31, and so on. The last digit represents LED 1. Each digit in X5) can be 0 through 4, representing the following possible LED statuses:

0 = off

1 = dim

2 = on (bright)

3 = slow blink

4 = fast blink

NOTE: Dual sized buttons, such as the input buttons on the MLC 62 IR D, each take up an entire button row and have

three LEDs apiece.

Example (MLC 62)E LC}00000001111121100000111124111104 ]

(This example is illustrated in the diagram below.)

In this LED status number, for example, the first digit on the right (LED 1) represents the red Transmit LED. Its status is 4, which indicates that it is blinking rapidly. The LEDs behind the display text (3 through 6) have a status of 1, which means they are dimly lit.

Buttons 7 and 8

(Button Row 4)

Not used

Buttons 5 and 6 (Button Row 3)

Buttons 3 and 4

Buttons 1 and 2

Transmit Green

(Button Row 2)

(Button Row 1)

 

 

 

 

 

 

Transmit

Volume Indicators

Behind “Volume” Text

Behind “Display” Text

Red

LED

0

0

0

0

0

0

0

1

1

1

1

1

2

1

1

0

0

0

0

0

1

1

1

1

2

4

1

1

1

1

0

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

On the MLC 64, the LEDs are numbered as follows:

1 =Transmit red

2 = Transmit green

3-6 = Display text LEDs 1 through 4 7 = Button row 1, first LED

8 = Button row 1, second LED

9-11 = Button row 2, LEDs 1 through 3 12-14 = Button row 3, LEDs 1 through 3 15-17 = Button row 4, LEDs 1 through 3 18-20 = Button row 5, LEDs 1 through 3

21-32 = Not used (Their status is always 0.)

Example (MLC 64)

E LC}

 

 

1

2

 

DISPLAY

3 – 6

7

ON

OFF

8

 

 

 

9

 

10

11

 

 

PC

 

12

 

13

14

 

LAPTOP

 

15

 

16

17

 

 

VIDEO

 

18

 

19

20

 

 

AUX

 

Extron

00000000000011111111122231111103 ]

In this MLC 64 example, the red Transmit LED shows status 3 (blinking slowly). The LEDs behind the Display text show status 1 (dimly lit). LEDs 9, 10, and 11 show status 2 (brightly lit) because the PC button (row 2) is active.

MLC 60 Series MediaLink Controllers • SIS Control

61

Page 67
Image 67