1.2Accessing Fryers for Servicing

THERMOSTATS

All fryers in the H50 Series have temperature probes located on the front centerline of each frypot. (Dual-vat frypots have two probes, one in each vat.) In this type thermostat, the probe resistance varies directly with the temperature. That is, as the temperature rises, so does resistance, at a rate of approximately 2 ohms for every 1º F. Circuitry in the controller monitors the probe resistance and controls burner firing when the resistance exceeds or falls below programmed temperatures (setpoints). The temperatures are programmed by means of a keypad on the face of the controller.

H50 Series fryers are also equipped with a high-limit thermostat. In the event that the fryer fails to properly control the oil temperature, the high-limit thermostat prevents the fryer from overheating to the flash point. The high-limit thermostat acts as a normally closed power switch that opens when exposed to temperatures above 425ºF to 450ºF (218ºC to 232ºC). The different types of thermostats have different part numbers for CE and Non-CE models, and are not interchangeable.

1.2Accessing Fryers for Servicing

1.3Cleaning the Gas Valve Vent Tube DANGER

Moving a fryer filled with cooking oil may cause spilling or splattering of the hot

liquid. Drain the fryer before attempting to relocate a fryer for servicing.

1.Shut off the gas supply to the unit. Unplug the power cords. Disconnect the unit from the gas supply.

2.Remove any attached restraining devices.

3.Relocate the fryer for service accessibility.

4.After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and plug in the electrical cords.

1.3Cleaning the Gas Valve Vent Tube

1.Set the fryer power switch and the gas valve to the OFF position.

2.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.

3.Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.

4.Remove the wire and blow through the tube to ensure it is clear.

5.Reinstall the tube and bend it so that the opening is pointing downward.

1-5