Management Commands

 

Command Reference

Control is always disabled.

Stop Bits: The number of Stop bits per character. The number of Stop bits is always 1.

Parity: The Parity Method used on the Serial Port. The Parity Method is always None.

Password Threshold: When the logon attempt threshold is reached on the console port, the system interface becomes silent for a specified amount of time before allowing the next logon attempt. (Use the silent time command to set this interval.) When this threshold is reached for Telnet, the Telnet logon interface closes.

Silent Time (sec): Use this command to set the amount of time the management console is inaccessible after the number of unsuccessful logon attempts exceeds the threshold set by the password threshold command.

7.5.2.2line console

This command is used to enter Line configuration mode

Syntax

line console

Default Setting

None

Command Mode

Global Config

7.5.2.3baudrate

This command specifies the communication rate of the terminal interface. The supported rates are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200.

Syntax

baudrate {1200 2400 4800 9600 19200 38400 57600 115200} no baudrate

no - This command sets the communication rate of the terminal interface to 9600.

Default Setting

9600

Command Mode

Line Config

Page 165
Image 165
Fujitsu BX600 manual Line console, Baudrate