Management Commands

 

Command Reference

Syntax

ip filter <ipaddr> no ip filter <ipaddr>

<ipaddr> - Configure a IP address to be a filter. No - Remove this filter IP address.

Default Setting

None

Command Mode

Global Config

7.5.2Serial Interface Commands

7.5.2.1show line console

This command displays serial communication settings for the IBP.

Syntax

show line console

Default Setting

None

Command Mode

Privileged Exec

Display Message

Serial Port Login Timeout (minutes): Specifies the time, in minutes, of inactivity on a Serial port connection, after which the IBP will close the connection. Any numeric value between 0 and 160 is allowed, the factory default is 5. A value of 0 disables the timeout.

Baud Rate: The default baud rate at which the serial port will try to connect. The available values are 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bauds.

Character Size: The number of bits in a character. The number of bits is always 8.

Flow Control: Whether Hardware Flow-Control is enabled or disabled. Hardware Flow