Q
A – Command Line Interface Set Command
Set Command
Sets a variety of switch parameters.
Authority Admin for all keywords except Alarm Clear, Beacon, and Pagebreak which are available with User authority.
Syntax set
alarm clear beacon [state] config [option] log [option] pagebreak [state] port [option] setup [option] switch [state]
Keywords alarm clear
Clears the alarm log. This keyword is available with User authority.
beacon [state]
Enables or disables the flashing of the
on
Enables the flashing beacon.
off
Disables the flashing beacon.
config [option]
Sets switch, port, alarm threshold, and zoning configuration parameters. Refer to the ”Set Config Command” on page
log [option]
Specifies the type of entries to be entered in the event log. Refer to the ”Set Log Command” on page
pagebreak [state]
Specifies how much information is displayed on the screen at a time according to the value given by [state]. This keyword is available with User authority. [state] can be one of the following:
on
Limits the display of information to 20 lines at a time. The page break functions affects the following commands: Alias (List, Members), Show (Alarm, Log), Zone (List, Members), Zoneset (List, Zones), Zoning (Active, List).
off
Allows continuous display of information without a break.