Q

A – Command Line Interface Set Command

Set Command

Sets a variety of switch parameters.

Authority Admin for all keywords except Alarm Clear, Beacon, and Pagebreak which are available with User authority.

Syntax set

alarm clear beacon [state] config [option] log [option] pagebreak [state] port [option] setup [option] switch [state]

Keywords alarm clear

Clears the alarm log. This keyword is available with User authority.

beacon [state]

Enables or disables the flashing of the Logged-In LEDs according to [state]. This keyword is available with User authority. [state] can be one of the following:

on

Enables the flashing beacon.

off

Disables the flashing beacon.

config [option]

Sets switch, port, alarm threshold, and zoning configuration parameters. Refer to the ”Set Config Command” on page A-29.

log [option]

Specifies the type of entries to be entered in the event log. Refer to the ”Set Log Command” on page A-38.

pagebreak [state]

Specifies how much information is displayed on the screen at a time according to the value given by [state]. This keyword is available with User authority. [state] can be one of the following:

on

Limits the display of information to 20 lines at a time. The page break functions affects the following commands: Alias (List, Members), Show (Alarm, Log), Zone (List, Members), Zoneset (List, Zones), Zoning (Active, List).

off

Allows continuous display of information without a break.

59022-06 A

A-27

Page 141
Image 141