Replacing a Failed Switch
The archive/restore works for all switches. However, the Restore menu item is not available for the inband switches. You can only restore a switch
1.At the failed switch:
a.Turn off the power and disconnect the AC cords.
b.Note port locations and remove the interconnection cables and SFPs.
c.Remove the failed switch.
2.At the replacement switch:
a.Mount the switch in the location where the failed switch was removed.
b.Install the SFPs using the same ports as were used on the failed switch.
CAUTION! Do not reconnect
c.Attach the AC cords and power up the switch.
3.Select the failed switch in the topology display. Open the Switch menu and select Delete.
4.Restore the configuration from the failed switch to the replacement switch:
a.Open the faceplate display for the replacement switch. Open the Switch menu and select Restore.
b.In the Restore dialog, enter the archive file from the failed switch or browse for the file.
c.Choose the Restore button.
5.Reconnect the
6.Reset the replacement switch to activate the configuration formerly possessed by the failed switch including the domain ID and the zoning database. Open the Switch menu and select Reset Switch.