Fujitsu BX600 System Utilities, 10.2.9, Sntp clock timezone name 0-12 0-59 before-utc after-utc

Models: BX600

1 274
Download 274 pages 29.29 Kb
Page 244
Image 244

錯誤! 找不到參照來源。

Command Reference

7.10.2.9

This command sets the time zone for the IBP’s internal clock.

Syntax

sntp clock timezone <name> <0-12> <0-59> {before-utc after-utc}

<name> - Name of the time zone, usually an acronym. (Range: 1-15 characters)

<0-12> - Number of hours before/after UTC. (Range: 0-12 hours)

<0-59> - Number of minutes before/after UTC. (Range: 0-59 minutes) before-utc - Sets the local time zone before (east) of UTC. after-utc - Sets the local time zone after (west) of UTC.

Default Setting

Taipei 08:00 After UTC

Command Mode

Global Config

7.11System Utilities

7.11.1clear

7.11.1.1 clear arp

This command causes all ARP entries of type dynamic to be removed from the ARP cache.

Syntax

clear arp

Default Setting

None

243