Installing the Cable Management Arm for Both Servers

The rack mounting kit for each server comes with the same cable management arm (CMA) assembly. The CMA installation and cable management procedures are the same for both servers.

Note – The CMA includes velcro straps to secure the cables inside the CMA. Do not install the velcro straps until you install the CMA, connect the cables, and place the cabling inside the CMA as described in the following procedures.

To Install the Cable Management Arm

Caution – Support the CMA during this installation. Do not allow the assembly to hang by its own weight until it is secured by all three attachment points.

1.Remove the tape from the CMA rail extension (on the left of the CMA) and remove the CMA rail extension.

2.Attach the CMA rail extension to rear left slide rail (FIGURE 2-8).

At the rear of the rack, plug the CMA rail extension into the end of the left sliding rail assembly. The tab at the front of the rail extension will click into place.

Chapter 2 Installing the SPARC Enterprise T5120 and T5220 Servers 25