compatability CLI as the default CLI (role=administrator, cli=alom). For more information on using the ALOM compatability CLI, refer to the Integrated Lights Out Manager 2.0 Supplement for SPARC Enterprise T5120 and T5220 Servers.

To Power On the System for the First Time

Tip – The serial terminal or a terminal emulator should be connected before you connect the power cables, or you will not see the system messages. The server goes into Standby mode and the ILOM service processor initializes as soon as the AC power cables are connected to the power source.

The service processor runs on the 3.3V standby voltage. As soon as AC power is connected to the system, the service processor powers on, runs diagnostics, and initializes the ILOM firmware.

1.Connect a terminal or a terminal emulator (PC or workstation) to the service processor serial management port.

Configure the terminal or terminal emulator with these settings:

9600 baud

8 bits

No parity

1 Stop bit

No handshake

Note – When you power on the server for the first time and you do not have a terminal or terminal emulator (PC or workstation) connected to the service processor serial management port, you will not see system messages. After connecting to the server with a terminal or terminal emulator, log into the ILOM CLI or the ALOM compatability CLI to get to the service processor console.

2.Turn on the terminal or terminal emulator.

3.Connect the AC power cables to Power Supply 0 and Power Supply 1, and watch the terminal for system messages.

Chapter 3 Powering On the System 43