2. Open an SSH session to connect to the service processor.
%ssh root@xx.xxx.xx.x
...
Are you sure you want to continue connecting (yes/no)? yes
...
Password: password (nothing displayed)
Waiting for daemons to initialize...
Daemons ready
Sun(TM) Integrated Lights Out Manager
Version 2.0.0.0
Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms.
3.Verify that the host is powered off.
If the host is not powered off, type the stop /SYS command.
4. Verify that the keyswitch_state parameter is set to normal.
5. Type the load command.
The load command updates the service processor flash image and the host firmware. The load command requires the following information:
■IP address of a TFTP server on the network that can access the flash image
■Full path name to the flash image that the IP address can access
The command usage is as follows:
load
where:
■
62 SPARC Enterprise T5120 and T5220 Servers Installation Guide • August 2007