2. Open an SSH session to connect to the service processor.

%ssh root@xx.xxx.xx.x

...

Are you sure you want to continue connecting (yes/no)? yes

...

Password: password (nothing displayed)

Waiting for daemons to initialize...

Daemons ready

Sun(TM) Integrated Lights Out Manager

Version 2.0.0.0

Copyright 2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms.

->

3.Verify that the host is powered off.

If the host is not powered off, type the stop /SYS command.

-> stop /SYS

4. Verify that the keyswitch_state parameter is set to normal.

-> set /SYS keyswitch_state=normal

5. Type the load command.

The load command updates the service processor flash image and the host firmware. The load command requires the following information:

IP address of a TFTP server on the network that can access the flash image

Full path name to the flash image that the IP address can access

The command usage is as follows:

load [-script] -source tftp://xxx.xxx.xx.xx/pathname

where:

-script– Do not prompt for confirmation and act as if yes was specified

62 SPARC Enterprise T5120 and T5220 Servers Installation Guide • August 2007