Galaxy 65 User Guide

Table 7–4

Warning events (Continued)

 

Event

 

Definition

Recommended Action

 

 

 

SYS OFFLINE

The system attempted to use Put

This Put Offline request may occur

FAIL

 

Offline on an SM, but the request was

when you press one of the module

 

 

rejected, probably because availability

latches to remove the module. In this

 

 

to the hosts would have been affected.

case, we recommend that you do not

 

 

 

take the module offline.

 

 

 

SYS ONLINE FAIL

The system attempted to Put Online a

The event gives a reason why the Put

 

 

newly inserted module, however the

Online failed. Examine this reason and

 

 

Put Online request failed.

take the appropriate action. If the

 

 

 

reason is DIAGNOSTIC FAIL, a

 

 

 

hardware problem was found with the

 

 

 

module. In this case, try replacing the

 

 

 

module with a different one.

 

 

 

UNWRITABLE

The SDRAM cache has battery

Either determine which drives are

CACHE

 

backed-up data, and the arrays

missing and reinstall them, or select

 

 

assigned to this data are not present.

Yes when asked if you want to discard

 

 

 

this data.

 

 

 

 

VOLT/TEMP

 

The analog-to-digital convertor

Check that the Galaxy 65 Subsystem’s

WARN

 

monitored a temperature or voltage in

fans are running. Check that the

 

 

the warning range.

ambient temperature is not too warm.

 

 

 

Check for any obstructions to the air

 

 

 

flow. See , ”Array Basics”, on page 89.

 

 

 

 

7.15.2 Errors

Error events let you know that something related to the Galaxy 65 Subsystem, module, or disk drives has failed and requires immediate attention. Table 7–5defines each error event and recommends the action you should take.

Table 7–5

Error events

 

 

 

 

 

Event

 

Definition

Recommended Action

 

 

 

 

ARRAY

 

One drive in the specified array

Replace the failed drive and add it as a

CRITICAL

 

failed and the array is running in

spare to the critical array. If you have

 

 

degraded mode (not fault tolerant).

dynamic spares enabled, you only need

 

 

 

to replace the drive. The system will

 

 

 

automatically reconstruct the array.

 

 

 

 

BATTERY

 

A failure in the battery pack or

Check that the battery is firmly connected

FAILED

 

charging interface has been

to the SM module. Refer to the Galaxy 65

 

 

detected.

Subsystem Getting Started Guide.

 

 

 

Replace the battery.

 

 

 

 

DISK CHAN

 

An error has occurred in

Check the cables on the channel.

FAILED

 

communicating on the disk channel.

 

 

 

 

 

80

Page 100
Image 100
Galaxy Metal Gear 65 manual Errors, SYS Online Fail