Galaxy 65 User Guide

2Select the array you want and press Enter. The array menu displays.

3Select Drive Status and press Enter

The drive status screen displays showing the drives that are members of the array and that are assigned as dedicated spares.

Use the or key to scroll through the drives. These are the drives that are currently members of the array.

4Press Esc to return to the Array Menu.

C.2.2 Stopping the Array Initialization Process

If you find that you need to change the disks or some other array configuration, you can stop the array initialization process.

Caution If you stop the initialization process, the array goes offline and its data is not available to users.

You must delete the array before you can use the drives in another array.

To stop the array initialization process:

1From the System Menu, select Array Menu and press Enter. The Select Array screen displays with a list of existing arrays.

2Select the array you want and press Enter. The array menu displays.

3Select Abort Initialization and press Enter

The system confirms that you want to stop the initialization process.