Configuring Galaxy 65
201
3Select the channel you want and press Enter.
4Select the initiator ID you want and press Enter.
The system confirms that you want to make the changes.
5Select Yes and press Enter to make the changes.
6Press Esc to return to the Configuration Menu.
G.6 Changing the Alarm Mute Setting
You can enable or disable the audible alarm that sounds when the Galaxy 65 Subsystem becomes too
hot, detects low or high voltage, or an array becomes critical or offline. Changing the mute setting lets
you turn off the alarm when it is sounding. You should turn it back on after resolving the problem.
You can also use the Mute button on the Galaxy 65 Ops Panel to turn off the alarm when it sounds.
The alarm sounds for temperature or voltage conditions (events). Warning events are generated when
the temperature or voltage enters the warning range. Shutdown events are generated when the
temperature or voltage enters the shutdown range. After reaching the shutdown range, the Galaxy 65
Subsystem will not function. You must resolve the problem and restart the Galaxy 65 Subsystem. If the
problem is not resolved, it will shut down again.
Alarm conditions trigger an event message that displays in the Disk Array Administrator software window
and in the event log. See D.5, ”Capturing the Event Log, Hardware, and Configuration Information”, on
page1 64.