Galaxy 65 Troubleshooting

Table 7–5

Error events (Continued)

 

 

 

 

 

 

 

Event

 

Definition

Recommended Action

 

 

 

 

 

 

SDRAM

 

A non correctable multiple-bit cache

Contact your Supplier.

 

UNCORR ECC

memory ECC error occurred.

 

 

 

 

 

 

VOLT/TEMP FAIL

The analog-to-digital convertor

Check that the Galaxy 65 Subsystem’s

 

 

 

monitored a temperature or voltage

fans are running. Check that the ambient

 

 

 

in the failure range.

temperature is not greater than 40°C. If

 

 

 

 

the Power Supply/Cooling modules have

 

 

 

 

no errors, replace the SM module where

 

 

 

 

the error occurred.

 

 

 

 

 

 

7.16 Setting Up and Viewing the Debug Log

You can set up additional logging when instructed by Rorke’s technical support personnel.

7.16.1Summary of Debug Log Capabilities

Single controller debug information: available from the Disk Array Administrator via the serial port on each controller module. Because of the direct connection of the serial port to a storage controller, debug information from this port can sometimes provide information unavailable from the Ethernet port, but this information will only be from one storage controller of the redundant storage controller pair. This information is available as long as one individual controller can boot, read its flash memory and communicate with it’s serial port.

Combined log debug information: available through the SAM via the Ethernet port on each controller module.

This set of logs will have several advantages over the single controller logs, but will also have a limitation in that collecting all the log data and passing it out via the Ethernet port requires a greater amount of hardware/software to be operational than for the single controller serial port case. Therefore, in some product failure scenarios the combined logs will potentiality have some holes in the debug data and it will also be necessary to review the single controller logs.

Use the following procedure to collect all three logs:

7.16.2Collecting Debug Logs

For most problem scenarios you should collect three logs, a combined log from one of the two SAM Ethernet port connections and a single controller log from each of the two Disk Array Administrator local serial port connections.

Note If one of the redundant controllers is down we recommend that you restart that Storage Manager module, if possible, before collecting the debug logs.

81

Page 101
Image 101
Galaxy Metal Gear 65 manual Setting Up and Viewing the Debug Log, Summary of Debug Log Capabilities, Collecting Debug Logs