Galaxy 65 User Guide

Table 1–1

Ops Panel Switch Functions (Default settings for Galaxy 65 LRC usage at 2Gb/s)

 

 

 

 

 

Switch

Function

Recommended

Definition

Number

 

 

Setting

 

 

 

 

 

 

1

Loop Select,

 

Off

LRC operates on two loops of 8 drives

 

Dual (2x8)

 

 

 

Mandatory

 

 

 

 

2

Not Used

Note: on Galaxy 65-FC2 enclosures this must be set On.

 

 

 

 

 

 

3

Not Used

 

 

 

 

 

 

 

 

 

 

4

Not Used

 

 

 

 

 

 

 

 

 

 

5 & 6

Not Used

 

 

 

 

 

 

 

 

 

 

7 & 8

Drive Loop Speed

Sw7

 

Sw8

 

 

Select

 

 

 

 

 

On

 

Off

Force 2Gb/s

 

 

 

 

 

 

 

 

 

 

 

Off

 

Off

Force 1Gb/s

 

 

 

 

 

 

9 & 10

Drive Addressing

Sw9

 

Sw10

 

 

Mode Selection

 

 

 

 

 

On

 

Off

Mode 2, 2x8 mode. Mandatory

 

 

 

 

 

 

 

 

 

11

SOFT SELECT

 

On

Select Functions using the hardware

 

 

 

 

 

switches

 

 

 

 

 

 

12

Not Used

 

 

 

 

 

 

 

 

 

 

Caution All mandatory settings must be observed in order for the Galaxy 65 system to function correctly. Note To set Host 1Gb use the Ethernet connected configurator.

1.3.3 Loop Resiliency Circuit Input/Output Module (FC-AL)

The Galaxy 65 storage Subsystem includes an enclosure with rear facing bays which house two Loop Resiliency Circuit (LRC) I/O modules with integrated Rorke Data Galaxy 65 RAID controller, known as Storage Managers (SM) modules. (see Figure 1–3)

The FC-AL Backplane incorporates two independent loops formed by Port Bypass Circuits within the LRC I/O modules.

The plug-in SM modules have been designed for integration into a Galaxy 65 storage Subsystem, utilizing FCAL interfacing with the host computer system.

Processors housed on the LRC modules provide enclosure management and interface to devices on the Backplane, PSU, LRC and Ops Panel, to monitor internal functions. These processors operate in a master slave configuration to allow failover.

The module incorporates the following LED indicators, shown in Figure 1–7:

Host Port 0 Signal Good (Green)

Host Port 1 Signal Good (Green)

Expansion Port 0 Rx Good (Green)

6

Page 26
Image 26
Galaxy Metal Gear 65 manual Loop Resiliency Circuit Input/Output Module FC-AL