Operation
15

Chapter 2

Operation

2.1 Before You Begin

Before powering up your Galaxy 65 enclosure please ensure that all the modules are firmly seated in their
correct bays.

2.2 Power On

Do not operate the Subsystem until the ambient temperature is within the specified operating range. If
the drives have been recently installed ensure they have had time to acclimatize before operating them.
Note Please refer to Section 2.3 for details of the Ops Panel LEDs and related fault conditions.
Follow the procedure below to power up the enclosure.
1Apply AC Mains power to the enclosure. Turn the Power Supply/Cooling modules to ON.
2On the Ops Panel, the Audible Alarm beeps once, all LEDs flash for 7 seconds then the Alarm double
beeps.
3All LEDs on the Ops Panel should be lit (Green) when the enclosure power is activated (and the disk drive
motors should start).
Note All LEDs on the Ops Panel should be lit Green at power up to indicate that the system is functioning
correctly. If any show Amber then a problem exists and the procedure in Chapter 4 ,”System Status”, on
page3 3 should be followed.
Important If mains power is lost for any reason, on restoration of power the enclosure will re-start
automatically.