Galaxy 65 User Guide

Table 7–2

Ops Panel Switch Functions

 

 

 

 

 

 

Switch

Function

Recommended

Definition

Number

 

 

Setting

 

1

Loop Select,

 

 

LRC operates on two loops of 8 drives

 

Dual (2x8)

 

Off

Mandatory

2

Not Used

Note: on Expansion enclosures this must be set On.

3

Not Used

 

 

 

4

Not Used

 

 

 

5 & 6

Not Used

 

 

 

7 & 8

Drive Loop Speed

Sw7

Sw8

 

 

Select

On

Off

Force 2Gb/s

 

 

Off

Off

Force 1Gb/s

9 & 10

Drive Addressing Mode Sw9

Sw10

 

 

Selection

On

Off

Mode 2

11

SOFT SELECT

On

 

Select Functions using the hardware

 

 

 

 

switches

12Not Used

Initiator ID assigned to each channel: The Galaxy 65 Subsystem assigns each of its FC disk channels one of the FC loop IDs (initiator IDs). The Initiator ID setting is set via the Disk Array Administrator. You can change the initiator ID assigned to each channel. You may need to do this if the default ID, 125, conflicts with an EMP ID. You have two options:

SOFT: Use this setting if you do not care whether the channel’s initiator ID changes when you power down and power up. This setting lets the FC loop initialization process determine the initiator ID.

Any number between 0 and 125: Select a specific number if you want the initiator ID to stay the same after you power down and power up. The Disk Array Administrator software cannot tell you which IDs are available. To be sure that you have successfully assigned the ID you want, check the ID after you restart the Galaxy 65 Subsystem. If the Galaxy 65 Subsystem cannot get the specified Loop ID during the loop initialization process, it will try to get a soft address.

To configure the FC disk channels:

1From the System Menu, select Configuration Menu and press Enter. The Configuration Menu displays.

2Select Channel Configuration and press Enter. The Select Disk Channel screen displays.

200

Page 220
Image 220