Galaxy 65 User Guide
12
1.6.4 PSU Safety and EMC Compliance1.6.5 Power Cord(minimum requirements)
1.6.6 EnvironmentSafety Compliance
UL 60950
IEC 60950
EN 60950
EMC Compliance CFR47 Part 15B Class A
EN55022
EN55024
Cord Type SV 0r SVT, 18 AWG minimum, 3 conductor
Plug 250V, 10A
Socket IEC 320 C-14, 250V, 15A
Table 1–2 Ambient Temperature and Humidity
Temperature Range Relative Humidity Max. Wet Bulb
Operational 5°C to 40°C 20% to 80%
non-condensing
23°C
Non-Operational 0°C to +50°C 8% to 80%
non-condensing
27°C
Storage 1°C to +60°C 8% to 80%
non-condensing
29°C
Shipping -40°C to +60°C 5% to 100%
non-precipitating
29°C
Altitude, Operational 0 to 3047 m (0 to 10,000ft)
Altitude, Non-Operational -305 to 12,192m (-1000 to 40,000ft)
Shock, Operational Vertical axis 5g peak 1/2 sine, 10ms
Shock, Non-Operational 30g 10ms 1/2 sine
Vibration, Operational 0.21grms 5-500 Hz Random
Vibration, Non-Operational 1.04grms 2-200 Hz Random
Vibration, Relocation 0.3g 2-200 Hz sine