Galaxy 65 Troubleshooting
63
7.4.1 System Faults7.4.2 Power Supply/Cooling Faults
Symptom Cause Action
1The SYSTEM LED will
illuminate AMBER on
the LRC
2Audible Alarm sound
The ESI processor
has detected an
internal fault (e.g.
failure of an
internal
communications
path)
1Check for other AMBER LED indications on the
Power Supply/Cooling modules. If there is a
PSU error present there may be a
communications problem with that Power
Supply/Cooling module. Remove and then re-fit
the module, if the problem persists then change
the module.
2Check for other AMBER LED indications on the
drives carriers. If none are evident then there
may either be an ESI processor problem or a
Backplane problem.
3Change the Ops Panel module (see 7.12.2).
Symptom Cause Action
1Ops Panel
FAULTLED AMBER
2An AMBER LED on
one or more Power
Supply/Cooling
Modules.
3Audible Alarm
Sounding.
1Any power
fault.
2A fan failure.
3A thermal
condition
which could
cause PSU
overheating.
1Check Power On/Off Switch on rear of Power
Supply/Cooling module is switched ON.(not
accessible on later models)
2Check AC Mains Connections to Power Supply/
Cooling module is live.
3Disconnect the Power Supply/Cooling module
from mains power and remove the module from
the system, Re-install: if problem persists,
replace Power Supply/Cooling Module.
4Reduce the ambient temperature.