GE 3800 Troubleshooting Consumer Support, Auxiliary controls on your Zoneline

Models: 3800

1 84
Download 84 pages 41.75 Kb
Page 8
Image 8
Auxiliary Controls—Terminal Connections

Auxiliary controls on your Zoneline.

Auxiliary Controls—Terminal Connections

The auxiliary controls are located behind the room cabinet beneath the access cover.

1 Remove the room cabinet. See the To Remove the Room Cabinet section.

2 Remove the screw from the access cover.

3 To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely.

4 After all desired connections have been made, replace the access cover and room cabinet.

The owner is responsible for making all connections and setting the appropriate dip switches.

Troubleshooting CAUTION:

Improper wiring may damage the Zoneline electronics. No common busing is permitted. Damage or erratic operation may result.

A separate wire pair must be run from each separate controlling switch to each individual Zoneline.

Motion Sensor Manual background

Door Sensor

External Fan

Central Desk Control

Manual background Common - Ground

White - Heater Yellow - Compressor Black - Solenoid Green - High Speed Fan Green - Low Speed Fan Red - 24 V AC only

Safety Instructions

Operating Instructions

Care and Cleaning

Tips

Motion Sensor (Obtained locally)

When connected, the wall mounted motion sensor will detect motion in the room and automatically set back the room temperature.

The door and motion sensors work together

to automatically set back the room temperature.

Troubleshooting

Consumer Support

The appropriate dip switch must be enabled.