GE EPM 5350 Chapter Programming Quick Reference, Entering the Programming Mode, Description

Models: EPM 5300 EPM 5200 EPM 5350

1 100
Download 100 pages 46.61 Kb
Page 89
Image 89
CHAPTER 15

CHAPTER 15: PROGRAMMING QUICK REFERENCE

CHAPTER 15

PROGRAMMING QUICK REFERENCE

15.1: Entering the Programming Mode

1.Hold PHASE/NEXT key and press AMPS key.

2.Display blanks and shows either a ‘0’, ‘1’, or ‘3’.

3.If ‘3’ is not displayed then press AMPS key until ‘3’ is displayed.

4.Release AMPS key and press PHASE/NEXT key, while ‘3’ is still displayed.

5.Display shows ‘333’ momentarily.

6.Upper display starts counting. Press PHASE/NEXT key when ‘5’ is displayed to register the ‘5’.

7.Repeat step 6 until ‘555’ has been registered.

15.2: Data Entry Sequence

1.At programmable numerical fields or Switch Pack fields, Press AMPS key to begin Data Entry Sequence.

2.The current setting moves to middle row of display and dashes appear in the bottom row. Press VOLTS key to toggle between available choices.

3.When a correct choice is selected, press AMPS key to store.

15.3: Programming Groups

Programming

Description

groups

 

 

 

0

Global Meter Setup—Integration Interval, Meter Address,

 

Communication Setting, Relay Settings

 

 

1

Full Scale Settings. Voltage Full Scale, Current Full Scale and Power

 

Function Full Scale.

 

 

2

Meter Calibration

 

 

3

Calibration Ratios

 

 

4

Volts and Current Limits

 

 

5

Power Function Limits

 

 

6

THD Limits

 

 

7

Imbalance Reversal Limits

 

 

8

DC Output Calibration

 

 

GE Industrial Systems

5300P Advanced Power Meter

85

Page 89
Image 89
GE EPM 5350 Chapter Programming Quick Reference, Entering the Programming Mode, Data Entry Sequence, Programming Groups