PLC Fault Table Messages for GMR

The following tables lists PLC Fault Table messages for GMR.. If you need additional help, call GE Fanuc Technical Service at 1±800±828±5747.

Code

100

100

101

101

101

100+ GBC ID

10009

10009

10010

10010

10011

10011

1

10102

10103

10104

10109

10110

10111

10112

10113

10114

10115

10116

10117

10119

10120

10121

10122

10123

10124

10129

10130

10131

10132

10133

10134

10135

10136

10137

10138

10139

10140

10141

10142

10143

10144

10145

Message

No CPU Clock

No PLC Clock Illegal state step Illegal trans code

Bad trans x from wwww

CFPT, 0 attempts wwww

GMRx ornge GBC g req GMRx bad GBC g req GMRx ornge GBC g rel GMRx bad GBC g rel GMRx ornge GBC g flt GMRx bad GBC g flt

Unauthorized GMR Access Incorrect GMR Version GMR Software Exception Invalid GMR Pointer Prog Checksum Timeout Invalid Bus Address Sync Not Possible Outputdiscrepancy Miscomp, no more retries GMRColdstart

GMR Warmstart Cannot get all GBCs Cannot do VME Write Invalid Switch Case Failed Disable Ops Failed Enable Ops Failed Set GMR Mode Failed DG Dgrams Failed Read Address Num dequeues = n ProgrammismatchA/B ProgrammismatchB/C ProgrammismatchA/C ProgrammismatchA/B&C ProgrammismatchB/A&C ProgrammismatchC/A&B ProgrammismatchA/B/C Program changed A Program changed B Program changed C ConfigmismatchA/B ConfigmismatchB/C ConfigmismatchA/C ConfigmismatchA/B&C ConfigmismatchB/A&C ConfigmismatchC/A&B

Meaning

There is no PLC clock present

There is no PLC clock present

Internal GMR error: invalid step

Internal GMR error: invalid transition code

Internal GMR error: attempted transition to invalid step

Number of attempts exhausted while trying to send a COMREQ

Out of range Bus Controller (g) was requested by GMRx module Unconfigured Bus Controller (g) was requested by GMRx module Out of range Bus Controller (g) was released by the GMRx module Unconfigured Bus Controller (g) was released by the GMRx module Out of Range Bus Controller (g) was faulted by the GMRx module Unconfigured Bus Controller (s) was faulted by the GMRx module

Initialization module was invoked with incorrectpassword Initialization module was called with incorrect version number An invalid call number was detected

Initialization module was invoked with invalid pointer for diagnostics area PLC didn't calculate the program checksum within 10 seconds Initialization detected bus addresses not equal to 29, 30, or 31 Synchronization cannot be performed

Output discrepancy detected

Sync detected miscompare GMR is performingcoldstart GMR is performing a warmstart

Cannot acquire all GBCs during initialization The VME Write to 7F3h was unsuccessful

An invalid case condition was detected during a switch

The Disable Outputs command (COMREQ) failed to complete successfully The Enable Outputs command (COMREQ) failed to complete successfully The Set GMR Mode command (COMREQ) failed to complete successfully

The Clear Datagrams Dequeue command (COMREQ) failed to complete successfully The Read Bus Address command (COMREQ) failed to complete successfully

N dequeue entries were dequeued at startup PLCs A and B program mismatch, C is not online PLCs B and C program mismatch, A is not online PLCs A and C program mismatch, B is not online PLC A program mismatch with B and C

PLC B program mismatch with A and C PLC C program mismatch with A and B All three PLCs mismatch

PLC A program changed PLC B program changed PLC C program changed

PLCs A&B config mismatch, C not online PLCs B and C config mismatch, A is not online PLCs A and C config mismatch, B is not online PLC A config mismatch with B and C

PLC B config mismatch with A and C PLC C config mismatch with A and B

5-18

GeniustModular Redundancy Flexible Triple Modular Redundant (TMR) System

GFK-0787B

 

User's Manual ±March 1995

 

Page 78
Image 78
GE GFK-0787B user manual PLC Fault Table Messages for GMR, Code