Message

ConfigmismatchA/B/C Config changed A Config changed B Config changed C

Unauthorized GMR Access Incorrect GMR Version GMR Software Exception Invalid GMR Pointer Comms Fail PLC A bus a Comms Fail PLC B bus a Comms Fail PLC C bus a Comms Fail PLC A bus b Comms Fail PLC B bus b Comms Fail PLC C bus b Big err rate, PLC A on a Big err rate, PLC A on b Big err rate, PLC B on a Big err rate, PLC B on b Big err rate, PLC C on a Big err rate, PLC C on b Invalid Switch Case

Unauthorized GMR access Incorrect version number Invalid call number Invalid GMR Pointer Invalid Block Size Invalid Digital Address InvalidAnalogAddress Invalid block type GMR3 Rr Ss comreq Fail GMRS/WExcept. %L Value out of range

IO Reset Seq Timeout IO Reset Seq Timeout IO Reset Seq Timeout IO Reset Seq Timeout IO Reset Seq Timeout

Unauthorized GMR Access

Invalid GMR Version

GMRS/WExcept. Call

GMRS/WExcept, %L

Invalid Switch Case

Unauthorized GMR Access GMRS/WExcept Null FH GMRS/WExceptI/OFH GMRS/WExcept call no ADL rack r slot s flt GMRS/WExcept %L GMR Invalid switch GMR config util invalid GMR cfg err GBCxx GMR cfg err GBCxxI/Oyy

GMR cfg err CPU type

Meaning

All three PLCs mismatch

PLC A config changed

PLC B config changed

PLC C config changed

Inter-PLC Comms module was invoked with incorrectpassword Inter-PLC Comms module has incorrect GMR version number Inter-PLC Comms module was called with invalid call number Inter-PLC Comms module was called with invalid data pointer Communications with PLC A has failed on bus a Communications with PLC B has failed on bus a Communications with PLC C has failed on bus a Communications with PLC A has failed on bus b Communications with PLC B has failed on bus b Communications with PLC C has failed on bus b

PLC detected a high data CRC failure rate communicating with PLC A on bus a PLC detected a high data CRC failure rate communicating with PLC A on bus b PLC detected a high data CRC failure rate communicating with PLC B on bus a PLC detected a high data CRC failure rate communicating with PLC B on bus b PLC detected a high data CRC failure rate communicating with PLC C on bus a PLC detected a high data CRC failure rate communicating with PLC C on bus b GMR2 software detected an illegal internal condition

Fault Processor Module was invoked with incorrectpassword Fault Processor Module was invoked with incorrect version number Call number was invalid

The supplied diagnostics pointer is out of range for the required memory type Incorrect block size was specified

Incorrect address of digital I/O was specified

Incorrect address of analog I/O was specified Block type currentlyunsupported

A COMREQ sent by GMR to a bus controller in rack r slot s has failed %L range error

Calculated value is out of range I/O reset timed out in step 2 I/O reset timed out in step 4 I/O reset timed out in step 6 I/O reset timed out in step 8 I/O reset timed out in step 10

I/OModulewasinvoked with the incorrectpassword

I/O Module S/W version does not match expectedversion

I/OModulewasinvoked with incorrect call number

I/OModulewasinvoked with out of range input parameters

No cases satisfied by switch condition

GMR Configuration Module was invoked with incorrectpassword GMR Configuration Module failed to load fault handler

GMR Configuration Module encountered an error loading the fault handler GMR Configuration Module detected call number exception

GMR Configuration Module failed to build active device list

GMR Configuration Module detected invalid diagnostic or errorreferences GMR Configuration Module detected invalid switch case

GMR Config Module detected incompatibility with configuration utility GMR Configuration Module detected invalid GBC record xx in the config data

GMR Configuration Module detected invalid GBC record yy in GBC record xx of the config data

GMR Configuration Module detected incompatible CPU type in the config data

GFK-0787B

Chapter 5 Diagnostics

5-19

Page 79
Image 79
GE GFK-0787B user manual Code