5

Code

10903

Message

User_IF±Invalid Table

Meaning

Module was called with extended mode table number when the module was in nor- mal mode

10903

Bad Table c (h)

Module was called with an invalid table number (c=requested table in decimal, h=requested table in hexadecimal)

10905

10906

10907

10908

User_IF±Invalid Range User_IF±Table Space No fault contacts

Bad blk loc r.s.b.d.

Start or end address parameter is out of range for the specified table type Destination parameter is out of range for the destination type of memory

An attempt was made to read fault contact data, but no fault contacts were configured

An attempt was made to read an I/O shutdown timer for an invalid block Generated by GMR_09.

10909 Bad GBC Loc r.s.

An attempt was made to read all I/O shutdown timers for an invalid GBC. Generated by GMR_09.

11001

Null GMR Configuration

Configuration Module has detected a Null GMR configuration

11101

Unauthorized GMR Access

GMR Configuration Module was invoked with incorrectpassword

11102

GMRS/WExcept. %L

%L parameter out of range

11201

Unauthorized GMR Access

GMR Configuration Module was invoked with the incorrectpassword

11202

GMRS/WExcept %L

%L parameter out of range

11401

Unauthorized GMR Access

GMR14 was invoked with the incorrectpassword

11402

Incorrect GMR Version

GMR14 version does not match the GMR system version number

11403

GMR Software Exception

Invalid call number was detected

11404

Invalid GMR Pointer

The error code pointer was out of bounds

11410

GMR1±IS x at y

GMR1 state machine went to step x (illegal). Step no. at offset y in GMR1 diagnostics

11411

GMR1±ST x at y

GMR1 state mach. exceeded allowed time in step x. Step no. at offset y in GMR1 diag-

 

 

nostics

11412

GMR1±IW x

GMR1 has output an illegal waycode of x

11413

GMR1±tmplt too small

GMR14 has detected an internal error condition

11415

GMR2±IS x at y

GMR2 state machine went to step x (illegal). Step no. at offset y in GMR2 diagnostics

11416

GMR2±ST x at y

GMR2 state mach. exceeded allowed time in step x. Step no. at offset y in GMR2 diag-

 

 

nostics

11417

GMR2±IW x

GMR2 has output an illegal waycode of x

11418

GMR2±tmplt too small

GMR14 has detected an internal error condition

11420

GMR3±IS x at y

GMR3 state machine went to step x (illegal). Step no. at offset y in GMR3 diagnostics

11421

GMR3±ST x at y

GMR3 state mach. exceeded allowed time in step x. Step no. at offset y in GMR3 diag-

 

 

nostics

11422

GMR3±IW x

GMR3 has output an illegal waycode of x

11423

GMR3±tmplt too small

GMR14 has detected an internal error condition

11430

GMR6±IS x at y

GMR6 state machine went to step x (illegal). Step no. at offset y in GMR6 diagnostics

11431

GMR6±ST x at y

GMR6 state mach. exceeded allowed time in step x. Step no. at offset y in GMR6 diag-

 

 

nostics

11432

GMR6±IW x

GMR6 has output an illegal waycode of x

11433

GMR6±tmplt too small

GMR14 has detected an internal error condition

11440

GMR8±IS x at y

GMR8 state machine went to step x (illegal). Step no. at offset y in GMR8 diagnostics

11441

GMR8±ST x at y

GMR8 state mach. exceeded allowed time in step x. Step no. at offset y in GMR8 diag-

 

 

nostics

11442

GMR8±IW x

GMR8 has output an illegal waycode of x

11443

GMR8±tmplt too small

GMR14 has detected an internal error condition

11445

GMR11±IS x at y

GMR11 state machine went to step x (illegal). Step no. at offset y in GMR11 diagnos-

 

 

tics

11446

GMR11±ST x at y

GMR11 state mach. exceeded allowed time in step x. Step no. at offset y in GMR11 diag-

 

 

nostics

11447

GMR11±IW x

GMR11 has output an illegal waycode of x

11448

GMR11±tmplt too small

GMR14 has detected an internal error condition

11450

GMR12±IS x at y

GMR12 state machine went to step x (illegal). Step no. at offset y in GMR12 diagnos-

 

 

tics

11451

GMR12±ST x at y

GMR12 state mach. exceeded allowed time in step x. Step no. at offset y in GMR12 diag-

 

 

nostics

11452

GMR12±IW x

GMR12 has output an illegal waycode of x

GFK-0787B

Chapter 5 Diagnostics

5-21

Page 81
Image 81
GE GFK-0787B user manual 10903