5.Add G_M_R10 to the library by pressing the Enter key.

Important . 6. When prompted for the number of paired input and output parameters, enter 2.

7.Press ESC to return to the Librarian menu.

Importing G_M_R10 from the Librarian to the Application Program

After G_M_R10 has been added to the Librarian, it can be imported to the Program

Folder that contains the application program at any time.

1.From the Librarian menu, select Import (F3).

2.In the upper window on the Import screen, select G_M_R10 from the files available in the Librarian.

The lower window lists the blocks currently in the selected folder.

Caution

Be sure you want to import the element before you continue. If you abort an import operation, it is not always possible to completely restore the folder to its original contents.

3.DO NOT RENAME G_M_R10.

4.Press the Enter key to begin the operation.

5.The original GMRxxyy folder contains a ªnullº G_M_R10 Program Block. This causes the prompt ªImport G_M_R10, Replacing Element in Folder?º Enter Y for Yes.