Real-Time Digital Output Status:

Digital output status is reflected in real-time updates on the Alarm Graphics Viewer if this option is selected on the Micro Definition tab of the Micro Form.

UL Certification:

Secure Perfect is a UL-listedGrade A system (UL 1076 Grade A Proprietary Burglary Requirements/UL 294 Access Control Requirements). Your installation must adhere to the requirements listed in the Certification section of the Secure Perfect Installation Manual, in order to qualify as UL-listed Grade A certified.

Badging:

Designer Upgrade: The integrated Badge Designer program is an upgraded version with many new features. On the Secure Perfect Badge Design Form, click Edit Badge Design to display a new windowpane. This is a separate program with its own toolbar. If you had a previous version of badge designer that created files with a .gdr extension, you will be prompted to save the file as a .dgn when you edit a badge design for the first time. Access the extensive Online Help system from the Badge Designer toolbar. Additionally, refer to the Badge Designer User Manual, and review the "What’s New" section. A PDF of the manual is provided on your documentation CD.

Badge Format: This option on the Administration menu allows an operator to design, import, or export custom badge formats for your Secure Perfect system. Custom magnetic stripe or Wiegand formats can be loaded and stored in the Secure Perfect database. After identifying the required custom format, the format is flashed to the micro. A new tab on the Micro Flash and Micro Parameter Configuration window allows you to configure custom badge formats.

Auto Shutdown of Secure Perfect Services:

This is a default option on the Client tab of the Client form. If selected, Secure Perfect Services will automatically shut down when the client application is closed. A list of prerequisite criteria must be met.

Manual Control Form:

Shortcut from Client Monitor Form to Manual Control Form: This feature allows the current operator to quickly locate a client, right-click and select the Manual Control form, and manually perform operations of the Secure Perfect system.

Mode Tab on the Manual Control Form: This feature allows the operator to select all or individual micros or clients for immediate change of mode from the Manual Control Form, on the new Mode Tab. The micro’s current real-time mode and address are also displayed.

Report Generation Upgrades:

Guard Tour History Report: This option on the Administration menu allows you to generate a report of completed Guard Tours, displaying tour activities such as start points, hits, invalid points, pauses, resumes, tour end points, tour time exceeded, manual start, and manual stops.

Administration Report: The list of report types has been expanded to include details of Alarm Routing and Bumping configurations and Badge Format (UBF) custom badge configurations.

Secure Perfect 6.1.1 User Manual

16

Page 18
Image 18
GE v6 user manual Real-Time Digital Output Status, UL Certification, Badging, Auto Shutdown of Secure Perfect Services