APB Out

Current badge APB current status of OUT, and attempted to gain

Invalid

access to an APB OUT reader.

TA In Invalid Current badge T&A current status of IN, and attempted to gain access to T&A IN reader.

TA Out Invalid Current badge T&A current status of OUT, and attempted to gain access to a T&A OUT reader.

Valid Floor

Elevator control with floor tracking is being used and the person was

 

granted access to the selected floor.

Invalid Floor Elevator control with floor tracking is being used and the person was not granted access to the selected floor.

Duress Valid ‘Grant Access on Duress’ is active on this system (selected on the Parameter Form) and door access was granted with a valid badge. This selection allows a duress alarm to be generated when a PIN code (with the final digit incremented by + 1) is entered.

Duress Invalid ‘Grant Access on Duress’ is not active on this system (not selected on the Parameter Form) and an attempted door access with a PIN code (with the final digit incremented by + 1) was denied.

Duress Valid ‘Grant Access on Duress’ is active on this system (selected on the

Open

Parameter Form) and door access was granted with a valid badge. This

 

selection allows a duress alarm to be generated when a PIN code (with

 

the final digit incremented by + 1) is entered. The door is open.

Duress Valid ‘Grant Access on Duress’ is active on this system (selected on the

 

No Passage

Parameter Form) and door access was granted with a valid badge. This

 

 

selection allows a duress alarm to be generated when a PIN code (with

 

 

the final digit incremented by + 1) is entered. The unlock time expired

 

 

and the door did not open.

Valid Open

‘Enable Valid No Passage’ is active on this reader. A valid badge read

 

 

occurs and the door opens.

Valid No

‘Enable Valid No Passage’ is active on this reader. A valid badge read

 

Passage

occurs but the door did not open within the configured unlock time. This

 

 

may be an indication of someone deciding not to pass through the door,

 

 

or an accidental read as someone passes a reader.

Invalid PIN

A badge was presented at a reader and an invalid PIN was entered.

 

 

This message displays for as many times as you enter an invalid PIN,

 

 

unless ‘Max Invalid Pin’ is configured on the Reader Form, Reader tab.

 

 

The badge does not grant access.

Max Invalid PIN ‘Max Invalid PIN Count’ is active on this reader and the number of invalid badge counts has reached the maximum, as configured on the Reader Form, Reader tab. The badge did not grant access and the badge is suspended.

The following are intrusion zone activities:

Zone Armed

By reader, DI, or manual control.

Zone Disarmed By reader, DI, or manual control.

Arm/Disarm

An alarm is in alarm state. Device or badge transaction failed.

 

 

Failed, Zone

 

 

 

Not Secure

 

 

Arm/Disarm

No badge transaction. The 10-second time period allowed for

 

 

Failed, Time

completion of the arm/disarm process at keypad and reader, has

 

 

Expired

expired.

 

Arm/Disarm

Intrusion Zone not assigned to access right or is invalid.

 

 

Failed, Invalid

 

 

 

Access Right

 

 

Arm/Disarm

Reader is not assigned to the zone.

 

 

 

Secure Perfect 6.1.1 User Manual

25

Page 27
Image 27