12.On the Micro Configuration tab, select the boards that are in the micro you are setting up. Click the desired board in the Boards and drag to the Configuration column. To delete a board from the Configuration column, select then right-click and select Delete.

13.Click Save to save the record. If there is any required information missing, a message will display listing those items that are incorrect or missing. Do not forget to save the record again once you fix those items.

14.When the micro record is created, the records for the associated readers, alarms, alarm groups, digital outputs, and digital output groups are also created with default data based on the boards you added on the Micro Configuration tab.

15.Use the Micro Utilities Form to set the micro online.

Creating a Direct-Connect Micro Record

Reference Topic:

Records Generation

1.On the Micro Definition tab of the Micro Form, default values will be filled in for Head of line and Badge Loading. Complete the following:

Enter the address of the micro. Enter the type of micro.

If this micro is the first micro on a string of micros, select Yes under Head of line. Otherwise, select No and select the head of line micro. If this is a downstream micro that you are adding, the micro directly upstream (towards the host) from it will need to be reset in order for it to recognize the micro you are adding.

Example:

If your line of micros looks like this: Host – Micro 1 – Micro 2

And you want to add Micro 3 to the end of the line so that it now looked like this: Host – Micro 1 – Micro 2 – Micro 3

Then you would need to reset Micro 2 in order for Micro 3 to be recognized. For connection type, select Direct.

Set Host keep alive time interval.

Enter the PC name of the host computer or navigate and select. Select a method.

2.On the Password tab, if you do not enter passwords, the default passwords (one-1, two-2, three-3, and four-4) are used. If you want to change the passwords, you can do so at any time.

3.On the Time Zone tab, a default time zone is filled in. Verify and adjust time zone settings as necessary.

4.On the Comments tab, enter any information you want or leave blank.

5.On the Events tab, you may want to schedule when APB and T&A are reset.

6.Select the Status tab to view information about the micro such as the firmware version. You can request the latest information by clicking Refresh.

7.On the Micro Configuration tab, select the boards that are in the micro you are setting up. Click the board you want and drag to the Configuration column.

8.To delete, select a board from the Configuration column, right-click and select Delete.

9.Click Save. If there is any required information missing, a window will display listing those items that are incorrect or missing. Don’t forget to save the record again once you fix those items.

10.When the micro record is created, the records for the associated readers, alarms, alarm groups, digital outputs, and digital output groups are also created with default data based on the boards you added on the Micro Configuration tab.

11.Use the Micro Utility Form to set the micro online.

Secure Perfect 6.1.1 User Manual

130

Page 132
Image 132
GE v6 user manual Creating a Direct-Connect Micro Record