GE v6 Alarm Graphics Viewer Shortcut Menu, Alarm Group, Alarm Point Right-Click Menu Options

Models: v6

1 269
Download 269 pages 54.7 Kb
Page 98
Image 98

Alarm Graphics Viewer Shortcut Menu

Operator permissions for the Alarm Graphics Viewer must be assigned to ‘Update’ in order to view and select right-click menu options. Points, alarms, DIs, and DOs do not display if not in the operator’s facility. For shortcut menu functionality, move your mouse pointer to an assigned point and click the right mouse button. The shortcut menu that displays with a right-click mouse button depends on the Point Type assigned.

Element

Alarm Monitor Form

Alarm Point Right-Click

Menu Options:

Alarm Monitor Form

Monitor On Indefinite

Monitor Off Indefinite

Monitor On Schedule Override

Monitor Off Schedule Override

Digit Input Point Right-Click Menu Options:

Enable On Indefinite

Enable Off Indefinite

Enable On Schedule Override

Enable Off Schedule Override

Digit Output Point Right-Click Menu Options:

Unlock Reader/On for Duration

Unlock Reader Indefinitely/On

Lock Reader/Off

Unlock Reader Schedule Override

Description

Displays the Alarm Monitor form. This is the right-click menu option when mouse pointer is not on an assigned map point.

Displays the Alarm Monitor form.

Activates the assigned alarm. The alarm will remain active until you manually turn it off.

Immediately deactivates the alarm.

Immediately activates this alarm and the schedule overrides any active setting.

Immediately deactivates this alarm and the schedule overrides any active setting.

Enables this DI and will remain enabled until you change the state manually.

Disables this DI and this DI will remain Off until you change the state manually.

Immediately activates this digital input and a schedule can override any active setting for this digital input.

Immediately deactivates the digital input and a schedule can override any active setting for this digital input.

Immediately unlocks the reader or turns on the DO and remains unlocked for the specified ‘On Time.’

Immediately unlocks the reader or turns on the DO associated with this reader and remains unlocked indefinately.

Immediately locks the reader or turns off the DO associated with this reader.

Immediately unlocks the reader or turns on the DO associated with this reader and the schedule overrides any active setting.

Alarm Group

Device Menu

The Alarm Group option opens the Alarm Group Form that allows you to assign alarms into groups or sets for scheduling purposes. Example: To apply a schedule to a series of alarms, apply the schedule to a group that contains the specific alarms.