Intrusion Zone Tab

Reference Topic:

Arm/Disarm an Intrusion Zone

Intrusion Zone Form

This tab allows you to edit or create an intrusion zone record and associate DI, DO, and devices such as readers and alarms in the operators’ selected facilities.

Number: Assign and enter a number for the intrusion zone, between 1 and 96. Duplicate numbers are allowed but not on the same micro.

Micro:

Select a micro from the drop-down list of available micros that will control this intrusion zone. This is a one-to-one relationship and establishes the zone source and intrusion/access points. The micro must be connected and online.

A Reader or Digital Input and Alarm must be selected in order to save this record.

Arm/Disarm DO: Select one DO from the drop-down list of DOs that will trigger when an Intrusion Zone is armed/disarmed. This is an optional assignment. This DO can be assigned to another Intrusion Zone.

Arm/Disarm DI: Select one DI for the drop-down list of available DIs of the Type Intrusion, as assigned on the Digital Input Form. This DI can arm/disarm an Intrusion Zone and is an optional assignment. This DI cannot be assigned to another Intrusion Zone.

When you unassign a DI, save this record. It is now available to re-assign this DI to another Intrusion Zone.

Last Status:

Date: Date of last zone history transaction on record.

Time: Time of last zone history transaction on record.

Status: Status as of last zone history transaction on record.

In order to refresh this status section, click off of this record then back or close then reopen the form

Devices

Assigned Readers: This list box displays a list of available, active readers in the same zone, belonging to the selected micro. You must assign at least one reader OR a digital input and alarm to an Intrusion Zone. The reader cannot be assigned to an elevator. Click Assign Readers to display a dialog box that enables you to assign active readers.

Assigned Alarms: This list box displays a list of intrusion alarms in the same zone, not already assigned, on the selected micro. This cannot be an external, DVMR, or a logical such as Host Comm or Lost Badge alarm. Click Assign Alarms to display a dialog box that enables you to assign alarms. This is an optional assignment.

Arm Delay (sec)

Arm Delay: Enter the number of seconds to delay the arming of this intrusion zone. This field accepts up to 255 seconds. This time limit should allow a person to pass into or out of a monitored area before the zone is armed.

If your system is UL-listed, the delay cannot exceed 60 seconds. Refer to the UL Certification Requirements in your Secure Perfect Installation Manual.